Implementing a negative-pressure isolation ward for a surge in airborne infectious patients

Reference Type Journal Article
Year of Publication
2017
Contributors Author: Shelly L. Miller PhD
Author: Nicholas Clements
Author: Steven A. Elliott
Author: Shobha S. Subhash MS
Author: Aaron Eagan MS
Author: Lewis J. Radonovich MD
Journal
American Journal of Infection Control
Volume
45
Journal Abbreviation
Am J of Infect Control
Issue
6
Pagination
652-659, 8 pages
Date Published
01/2017
Language
Download citation
ISSN
1527-3296
Publisher
Abstract

BACKGROUND:
During a large-scale airborne infectious disease outbreak, the number of patients needing hospital-based health care services may exceed available negative-pressure isolation room capacity.

METHODS:
To test one method of increasing hospital surge capacity, a temporary negative-pressure isolation ward was established at a fully functioning hospital. Negative pressure was achieved in a 30-bed hospital ward by adjusting the ventilation system. Differential pressure was continuously measured at 22 locations, and ventilation airflow was characterized throughout the ward.

RESULTS:
The pressure on the test ward relative to the main hospital hallway was -29 Pa on average, approximately 10 times higher than the Centers for Disease Control and Prevention guidance for airborne infection control. No occurrences of pressure reversal occurred at the entrances to the ward, even when staff entered the ward. Pressures within the ward changed, with some rooms becoming neutrally or slightly positively pressurized.

CONCLUSIONS:
This study showed that establishing a temporary negative-pressure isolation ward is an effective method to increase surge capacity in a hospital.

URL
https://www.ncbi.nlm.nih.gov/pubmed/28330710